Model-Specific Specifications (200 V Class)

Table 1. Rating (200 V Class)

Model

2004

2006

2008

2010

2012

2018

2021

2030

2042

Maximum Applicable Motor Output (kW)

HD 1

0.55

0.75

1.1

1.5

2.2

3

3.7

5.5

7.5

ND 2

0.75

1.1

1.5

2.2

3

3.7

5.5

7.5

11

Input

Rated Input Current (A)

HD (AC)

3.6

4.8

6.7

8.9

12.7

17

20.7

30

40.3

HD (DC)

4.5

5.9

8.2

10.9

15.6

20.8

25.3

36.8

49.4

ND (AC)

4.8

6.7

8.9

12.7

17

20.7

30

40.3

52

ND (DC)

5.9

8.2

10.9

15.6

20.8

25.3

36.8

49.4

71.3

Output

Rated Output Capacity (kVA)

HD 3

1.2

1.9

2.6

3.0

4.2

5.3

6.7

9.5

12.6

ND 4

1.3

2.3

3.0

3.7

4.6

6.7

8.0

11.4

16.0

Rated Output Current (A)

HD

3.2

5

6.9

8

11

14

17.5

25

33

ND

3.5

6

8

9.6

12.2

17.5

21

30

42

Overload Tolerance

  • HD: 150% of the rated output current for 60 seconds. The permitted frequency of overload is one time each 10 minutes.

  • ND: 110% of the rated output current for 60 seconds. The permitted frequency of overload is one time each 10 minutes.

Note:

Derating can be necessary for applications that start and stop frequently.

Carrier Frequency

HD: 8 kHz without derating the drive capacity.

ND: 2 kHz without derating the drive capacity.

Derate the drive capacity to use values to 15 kHz maximum.

Maximum Output Voltage

Three-phase 200 V to 240 V

Note:

The maximum output voltage is proportional to the input voltage.

Maximum Output Frequency

  • Advanced Open Loop Vector Control (AOLV) and EZ Open Loop Vector Control (EZOLV): 120 Hz

  • Closed Loop V/f Control (CL-V/f), Closed Loop Vector Control (CLV), Advanced Open Loop Vector Control for PM (AOLV/PM), and Closed Loop Vector Control for PM (CLV/PM): 400 Hz

  • V/f Control (V/f), Open Loop Vector Control (OLV), and Open Loop Vector Control for PM (OLV/PM): 590 Hz

Measures for Harmonics

DC reactor

External options

Braking Device

Braking Transistor

Standard internal characteristics

EMC Filter

EMC Filter

IEC 61800-3, C3

Factory option

  • Models 2xxxB: There is a category C3 EMC filter in the drive.

Power Supply

Rated Voltage, Rated Frequency

  • Three-phase AC power supply 200 V to 240 V at 50/60 Hz?

  • DC power supply 270 V to 340 V

Permitted Voltage Fluctuation

-15% to +10%

Permitted Frequency Fluctuation

±5%

Input Power (kVA)

HD

1.5

2.0

2.8

3.7

5.3

7.1

8.6

12.5

16.8

ND

2.0

2.8

3.7

5.3

7.1

8.6

12.5

16.8

21.6

 
Table 2. Rating (200 V Class)

Model

2056

2070

2082

2110

2138

Maximum Applicable Motor Output (kW)

HD 1

11

15

18.5

22

30

ND 2

15

18.5

22

30

37

Input

Rated Input Current (A)

HD (AC)

58.2

78.4

96

82

111

HD (DC)

71.3

96

118

100

136

ND (AC)

78.4

96

114

111

136

ND (DC)

96

117.6

139

136

166

Output

Rated Output Capacity (kVA)

HD 3

17.9

22.9

28.6

33.5

43.8

ND 4

21.3

26.7

31.2

41.9

52.6

Rated Output Current (A)

HD

47

60

75

88

115

ND

56

70

82

110

138

Overload Tolerance

  • HD: 150% of the rated output current for 60 seconds. The permitted frequency of overload is one time each 10 minutes.

  • ND: 110% of the rated output current for 60 seconds. The permitted frequency of overload is one time each 10 minutes.

Note:

Derating can be necessary for applications that start and stop frequently.

Carrier Frequency

HD: 8 kHz without derating the drive capacity.

ND: 2 kHz without derating the drive capacity.

Derate the drive capacity to use values to 15 kHz maximum.

Maximum Output Voltage

Three-phase 200 V to 240 V

Note:

The maximum output voltage is proportional to the input voltage.

Maximum Output Frequency

  • Advanced Open Loop Vector Control (AOLV) and EZ Open Loop Vector Control (EZOLV): 120 Hz

  • Closed Loop V/f Control (CL-V/f), Closed Loop Vector Control (CLV), Advanced Open Loop Vector Control for PM (AOLV/PM), and Closed Loop Vector Control for PM (CLV/PM): 400 Hz

  • V/f Control (V/f), Open Loop Vector Control (OLV), and Open Loop Vector Control for PM (OLV/PM): 590 Hz

Measures for Harmonics

DC reactor

External options

Standard internal characteristics

Braking Device

Braking Transistor

Standard internal characteristics

EMC Filter

EMC Filter

IEC 61800-3, C3

Factory option

  • Models 2xxxB: There is a category C3 EMC filter in the drive.

Power Supply

Rated Voltage, Rated Frequency

  • Three-phase AC power supply 200 V to 240 V at 50/60 Hz?

  • DC power supply 270 V to 340 V

Permitted Voltage Fluctuation

-15% to +10%

Permitted Frequency Fluctuation

±5%

Input Power (kVA)

HD

24.2

32.6

39.9

34.1

46.1

ND

32.6

39.9

47.4

46.1

56.5

Table 3. Rating (200 V Class)

Model

2169

2211

2257

2313

2360

2415

Maximum Applicable Motor Output (kW)

HD 1

37

45

55

75

90

110

ND 2

45

55

75

90

110

-

Input

Rated Input Current (A)

HD (AC)

136

164

200

271

324

394

HD (DC)

166

201

245

331

396

482

ND (AC)

164

200

271

324

394

-

ND (DC)

201

245

331

396

482

-

Output

Rated Output Capacity (kVA)

HD 3

55.3

68.6

81.9

108

132

158

ND 4

64.4

80.4

97.9

119

137

?

Rated Output Current (A)

HD

145

180

215

283

346

415

ND

169

211

257

313

360

-

Overload Tolerance

  • HD: 150% of the rated output current for 60 seconds. The permitted frequency of overload is one time each 10 minutes.

  • ND: 110% of the rated output current for 60 seconds. The permitted frequency of overload is one time each 10 minutes.

Note:

Derating can be necessary for applications that start and stop frequently.

Carrier Frequency

HD: 5 kHz without derating the drive capacity.

ND: 2 kHz without derating the drive capacity.

Derate the drive capacity to use values to 10 kHz maximum.

Maximum Output Voltage

Three-phase 200 V to 240 V

Note:

The maximum output voltage is proportional to the input voltage.

Maximum Output Frequency

  • Advanced Open Loop Vector Control (AOLV) and EZ Open Loop Vector Control (EZOLV): 120 Hz

  • Closed Loop V/f Control (CL-V/f), Closed Loop Vector Control (CLV), Advanced Open Loop Vector Control for PM (AOLV/PM), and Closed Loop Vector Control for PM (CLV/PM): 400 Hz

  • V/f Control (V/f), Open Loop Vector Control (OLV), and Open Loop Vector Control for PM (OLV/PM): 590 Hz

Measures for Harmonics

DC reactor

Standard internal characteristics

Braking Device

Braking Transistor

External options

EMC Filter

EMC Filter

IEC 61800-3, C3

Factory option

  • Models 2xxxB: There is a category C3 EMC filter in the drive.

Power Supply

Rated Voltage, Rated Frequency

  • Three-phase AC power supply 200 V to 240 V at 50/60 Hz?

  • DC power supply 270 V to 340 V

Permitted Voltage Fluctuation

-15% to +10%

Permitted Frequency Fluctuation

±5%

Input Power (kVA)

HD

56.5

68.2

83.1

113

135

164

ND

68.2

83.1

113

135

164

-

1

The maximum applicable motor output complies with 208 V motor ratings as specified in NEC Table 430.250. The rated output current of the drive output amps must be equal to or more than the motor rated current.

2

The maximum applicable motor output is based on 4-pole, general-purpose 220 V motor ratings. The rated output current of the drive output amps must be equal to or more than the motor rated current.

3

The rated output capacity is calculated with a rated output voltage of 208 V.

4

The rated output capacity is calculated with a rated output voltage of 220 V.