No.

(Hex.)

Name

Description

Default

(Range)

Ref.

n7-01

(3111)

Expert

Damping Gain for Low Frequency

Sets the oscillation suppression gain for the low speed range.

1.0

(0.1 - 10.0)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

n7-05

(3115)

Expert

Response Gain for Load Changes

Sets the response gain related to changes in the load.

100

(10 - 1000)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

n7-07

(3117)

Expert

Speed Calculation Gain1

Sets the speed calculation gain during usual operation. Usually it is not necessary to change this setting.

15.0

(1.0 - 50.0)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

n7-08

(3118)

Expert

Speed Calculation Gain2

Sets the speed calculation gain during a speed search.

25.0

(1.0 - 50.0)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

n7-10

(311A)

Expert

Pull-in Current Switching Speed

Sets the speed range to operate with the pull-in current command. Drive rated frequency = 100% value. If there is a large quantity of oscillation when you operate in the low speed range, increase the setting value.

10.0%

(0.0 - 100.0%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

n7-11

(311B)

Expert

Drv Mode Switch Hysteresis Band

Usually it is not necessary to change this setting. Sets the hysteresis level for Switching Speed set in n7-10 [Pull-in Current Switching Speed].

When the speed is lower than n7-10 + n7-11 during acceleration, the drive enables pull-in current.

Note:
  • When the drive accelerates, it enables these settings:

    • Motor speed ≤ n7-10 + n7-11: n8-51 [Pull-in Current @ Acceleration]

    • Motor speed > n7-10 + n7-11: b8-01 [Energy Saving Control Selection]

  • If there is a large quantity of oscillation when you operate in the low speed range, increase the setting value.

  • When it is most important to save energy in the low speed range, decrease the setting value.

5.0%

(1.0 - 20.0%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

n7-13

(311D)

Expert

Driving Method Switching Time

Sets a time to enable the pull-in current commands.

If there is a large quantity of oscillation at speeds around n7-10 [Pull-in Current Switching Speed], decrease the setting in 20 ms decrements.

100 ms

(0 - 1000 ms)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

n7-17

(3122)

Resistance TemperatureCorrection

Sets the function to adjust for changes in the motor resistance value caused by changes in the temperature.

0
Invalid
 
1
Valid (Only 1 time)
 
2
Valid (Every time)
 

1

(0 to 2)

Details