A
|
Time display area
|
Shows the current time. Set the time on the default settings screen.
Note:
The time display flashes when you use the data log function.
|
|
B
|
Forward run/Reverse indication
|
Shows direction of motor rotation.
Note:
In DriveWorksEZ operation, FWD or REV flash.
|
|
C
|
Ready
|
The screen will show Rdy when the drive is ready for operation or when the drive is running.
|
|
D
|
Mode display area
|
Shows the name of the current mode or screen.
|
|
E
|
Frequency reference source indicator
|
Shows the current frequency reference source.
-
KPD: keypad
-
AI: analog input terminal (terminals A1 to A3)
-
COM: MEMOBUS/Modbus communications
-
OPT: option card
-
RP: pulse train input terminal (terminal RP)
|
|
F
|
Data display area
|
Shows parameter values, monitor values, and details of the results of operations.
|
|
G
|
Function keys 1 to 3 (F1 to F3)
|