E2-01

(030E)

Motor Rated Current (FLA)

Sets the motor rated current in amps.

Determined by o2-04, C6-01

(10% to 200% of the drive rated current)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E2-02

(030F)

Motor Rated Slip

Sets motor rated slip.

Determined by o2-04, C6-01

(0.000 - 20.000 Hz)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E2-03

(0310)

Motor No-Load Current

Sets the no-load current for the motor in amps when operating at the rated frequency and the no-load voltage.

Determined by o2-04, C6-01

(0 to E2-01)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E2-04

(0311)

Motor Pole Count

Sets the number of motor poles.

Note:
  • When A1-02 = 0, 1, 3 [Control Method Selection = V/f, CL-V/f, CLV], the maximum value is 120.

  • When A1-02 = 2, 4 [OLV, AOLV], the maximum value is 48.

4

(2 - 120)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E2-05

(0312)

Motor Line-to-Line Resistance

Sets the line-to-line resistance for the motor stator windings.

Note:

On drive models 4810 to 4H12, the unit is mΩ, and the setting range is 0.000 mΩ to 65.000 mΩ.

Determined by o2-04, C6-01

(0.000 - 65.000 Ω)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E2-06

(0313)

Motor Leakage Inductance

Sets the voltage drop from motor leakage inductance when the motor is operating at the rated frequency and rated current. This value is a percentage of Motor Rated Voltage.

Determined by o2-04, C6-01

(0.0 - 60.0%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E2-07

(0314)

Motor Saturation Coefficient 1

Sets the motor iron-core saturation coefficient at 50% of the magnetic flux.

0.50

(0.00 - 0.50)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E2-08

(0315)

Motor Saturation Coefficient 2

Sets the motor iron-core saturation coefficient at 75% of the magnetic flux.

0.75

(E2-07 - 0.75)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E2-09

(0316)

Expert

Motor Mechanical Loss

Sets the mechanical loss of the motor. It is set as a percentage of E2-11 [Motor Rated Power]. Usually it is not necessary to change this setting.

0.0%

(0.0 - 10.0%)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E2-10

(0317)

Motor Iron Loss

Sets the motor iron loss.

Determined by o2-04, C6-01

(0 - 65535 W)

Details

No.

(Hex.)

Name

Description

Default

(Range)

Ref.

E2-11

(0318)

Motor Rated Power

Sets the motor rated output in the units from o1-58 [Motor Power Unit Selection].

Note:

On drive models 2xxx, and 4002 to 4675, the setting unit is 0.01 kW. The setting range is 0.00 kW to 650.00 kW (0.00 HP to 650.00 HP).

On drive models 4810 to 4H12, the setting unit is 0.1 kW. The setting range is 0.0 kW to 1000.0 kW (0.0 HP to 1340.5 HP).

Determined by o2-04, C6-01

(0.00 - 1000.0)

Details