Model-Specific Specifications (400 V Class)

Table 1. Rating (400 V Class)

Model

Duty Rating

4002

4004

4005

4007

4009

4012

4018

4023

Maximum Applicable Motor Output 1 (kW)

HD

0.55

1.1

1.5

2.2

3.0

4.0

5.5

7.5

ND

0.75

1.5

2.2

3.0

4.0

5.5

7.5

11

Input

Rated Input Current (A)

HD (AC)

1.9

3.5

4.7

6.7

8.9

11.7

15.8

21.2

HD (DC)

2.3

4.3

5.8

8.2

10.9

14.3

19.4

26.0

ND (AC)

2.5

4.7

6.7

8.9

11.7

15.8

21.2

30.6

ND (DC)

3.1

5.8

8.2

10.9

14.3

19.4

26.0

37.5

Output

Rated Output Capacity 2 (kVA)

HD

1.2

2.2

3.2

3.6

4.7

6.1

10

12

ND

1.4

2.7

3.6

4.7

5.9

7.8

12

15

Rated Output Current (A)

HD

1.8

3.4

4.8

5.5

7.2

9.2

14.8

18

ND

2.1

4.1

5.4

7.1

8.9

11.9

17.5

23.4

Overload Tolerance

  • HD: 150% of the rated output current for 60 seconds. The permitted frequency of overload is one time each 10 minutes.

  • ND: 110% of the rated output current for 60 seconds. The permitted frequency of overload is one time each 10 minutes.

Note:

Derating can be necessary for applications that start and stop frequently.

Carrier Frequency

HD: 8 kHz without derating the drive capacity.

ND: 2 kHz without derating the drive capacity.

Derate the drive capacity to use values to 15 kHz maximum.

Maximum Output Voltage

Three-phase 380 V to 480 V

Note:

The maximum output voltage is proportional to the input voltage.

Maximum Output Frequency

  • Advanced Open Loop Vector Control (AOLV) and EZ Open Loop Vector Control (EZOLV): 120 Hz

  • Closed Loop V/f Control (CL-V/f), Closed Loop Vector Control (CLV), Advanced Open Loop Vector Control for PM (AOLV/PM), and Closed Loop Vector Control for PM (CLV/PM): 400 Hz

  • V/f Control (V/f), Open Loop Vector Control (OLV), and Open Loop Vector Control for PM (OLV/PM): 590 Hz

Measures for Harmonics

DC reactor

External options

Braking Device

Braking Transistor

Standard internal characteristics

EMC Filter

EMC Filter

IEC 61800-3, C3

Factory option

  • Models 4xxxB: There is a category C3 EMC filter in the drive.

Power Supply

Rated Voltage, Rated Frequency

  • Three-phase AC power supply 380 V to 480 V at 50/60 Hz

  • DC power supply 513 V to 679 V

Permitted Voltage Fluctuation

-15% to +10%

Permitted Frequency Fluctuation

±5%

Input Power (kVA)

HD

1.5

2.8

3.7

5.3

7.1

9.3

13

17

ND

2.0

3.7

5.3

7.1

9.3

13

17

24

 
Table 2. Rating (400 V Class)

Model

Duty Rating

4031

4038

4044

4060

4075

4089

4103

Maximum Applicable Motor Output 1 (kW)

HD

11

15

18.5

22

30

37

45

ND

15

18.5

22

30

37

45

55

Input

Rated Input Current (A)

HD (AC)

30.6

41.3

50.5

43.1

58.3

71.5

86.5

HD (DC)

37.5

50.5

61.9

52.8

71.4

87.5

106.0

ND (AC)

41.3

50.5

59.7

58.3

71.5

86.5

105

ND (DC)

50.5

61.9

73.2

71.4

87.5

106.0

129

Output

Rated Output Capacity 2 (kVA)

HD

16

20

26

30

39

49

60

ND

20

25

29

39

49

59

68

Rated Output Current (A)

HD

24

31

39

45

60

75

91

ND

31

38

44

59.6

74.9

89.2

103

Overload Tolerance

  • HD: 150% of the rated output current for 60 seconds. The permitted frequency of overload is one time each 10 minutes.

  • ND: 110% of the rated output current for 60 seconds. The permitted frequency of overload is one time each 10 minutes.

Note:

Derating can be necessary for applications that start and stop frequently.

Carrier Frequency

HD: 8 kHz without derating the drive capacity.

ND: 2 kHz without derating the drive capacity.

Derate the drive capacity to use values to 15 kHz maximum.

Maximum Output Voltage

Three-phase 380 V to 480 V

Note:

The maximum output voltage is proportional to the input voltage.

Maximum Output Frequency

  • Advanced Open Loop Vector Control (AOLV) and EZ Open Loop Vector Control (EZOLV): 120 Hz

  • Closed Loop V/f Control (CL-V/f), Closed Loop Vector Control (CLV), Advanced Open Loop Vector Control for PM (AOLV/PM), and Closed Loop Vector Control for PM (CLV/PM): 400 Hz

  • V/f Control (V/f), Open Loop Vector Control (OLV), and Open Loop Vector Control for PM (OLV/PM): 590 Hz

Measures for Harmonics

DC reactor

External options

Standard internal characteristics

Braking Device

Braking Transistor

Standard internal characteristics

EMC Filter

EMC Filter

IEC 61800-3, C3

Factory option

  • Models 4xxxB: There is a category C3 EMC filter in the drive.

Power Supply

Rated Voltage, Rated Frequency

  • Three-phase AC power supply 380 V to 480 V at 50/60 Hz

  • DC power supply 513 V to 679 V

Permitted Voltage Fluctuation

-15% to +10%

Permitted Frequency Fluctuation

±5%

Input Power (kVA)

HD

24

33

40

34

46

57

69

ND

33

40

48

46

57

69

84

Table 3. Rating (400 V Class)

Model

Duty Rating

4140

4168

4208

4250

4296

4371

4389

Maximum Applicable Motor Output 1 (kW)

HD

55

75

90

110

132

160

185

ND

75

90

110

132

160

200

220

Input

Rated Input Current (A)

HD (AC)

105

142

170

207

248

300

373

HD (DC)

129

174

209

254

304

367

457

ND (AC)

142

170

207

248

300

373

410

ND (DC)

174

209

254

304

367

457

502

Output

Rated Output Capacity 2(kVA)

HD

74

99

118

142

171

200

244

ND

92

111

137

165

195

244

256

Rated Output Current (A)

HD

112

150

180

216

260

304

371

ND

140

168

208

250

296

371

389

Overload Tolerance

  • HD: 150% of the rated output current for 60 seconds. The permitted frequency of overload is one time each 10 minutes.

  • ND: 110% of the rated output current for 60 seconds. The permitted frequency of overload is one time each 10 minutes.

Note:

Derating can be necessary for applications that start and stop frequently.

Carrier Frequency

HD: 5 kHz without derating the drive capacity.

ND: 2 kHz without derating the drive capacity.

Derate the drive capacity to use values to 10 kHz maximum.

Maximum Output Voltage

Three-phase 380 V to 480 V

Note:

The maximum output voltage is proportional to the input voltage.

Maximum Output Frequency

  • Advanced Open Loop Vector Control (AOLV) and EZ Open Loop Vector Control (EZOLV): 120 Hz

  • Closed Loop V/f Control (CL-V/f), Closed Loop Vector Control (CLV), Advanced Open Loop Vector Control for PM (AOLV/PM), and Closed Loop Vector Control for PM (CLV/PM): 400 Hz

  • V/f Control (V/f), Open Loop Vector Control (OLV), and Open Loop Vector Control for PM (OLV/PM): 590 Hz

Measures for Harmonics

DC reactor

Standard internal characteristics

Braking Device

Braking Transistor

Standard internal characteristics

External options

EMC Filter

EMC Filter

IEC 61800-3, C3

Factory option

  • Models 4xxxB: There is a category C3 EMC filter in the drive.

Power Supply

Rated Voltage, Rated Frequency

  • Three-phase AC power supply 380 V to 480 V at 50/60 Hz

  • DC power supply 513 V to 679 V

Permitted Voltage Fluctuation

-15% to +10%

Permitted Frequency Fluctuation

±5%

Input Power (kVA)

HD

84

113

135

165

198

239

297

ND

113

135

165

198

239

297

327

Table 4. Rating (400 V Class)

Model

Duty Rating

4453

4568

4675

4810

4930

4H11

4H12

Maximum Applicable Motor Output 1 (kW)

HD

220

250

315

400

450

500

560

ND

250

315

355

450

500

560

630

Input

Rated Input Current (A)

HD (AC)

410

465

584

783

830

976

1031

HD (DC)

502

569

715

959

1017

1195

1262

ND (AC)

465

584

657

879

922

1091

1158

ND (DC)

569

715

805

1077

1129

1337

1418

Output

Rated Output Capacity 2 (kVA)

HD

272

298

398

474

533

612

717

ND

298

374

444

533

612

717

790

Rated Output Current (A)

HD

414

453

605

720

810

930

1090

ND

453

568

675

810

930

1090

1200.0

Overload Tolerance

  • HD: 150% of the rated output current for 60 seconds. The permitted frequency of overload is one time each 10 minutes.

  • ND: 110% of the rated output current for 60 seconds. The permitted frequency of overload is one time each 10 minutes.

Note:

Derating can be necessary for applications that start and stop frequently.

Carrier Frequency

HD: 2 kHz without derating the drive capacity.

ND: 2 kHz without derating the drive capacity.

Derate the drive capacity to use values to 5 kHz maximum.

Maximum Output Voltage

Three-phase 380 V to 480 V

Note:

The maximum output voltage is proportional to the input voltage.

Maximum Output Frequency

  • Advanced Open Loop Vector Control (AOLV) and EZ Open Loop Vector Control (EZOLV): 120 Hz

  • Closed Loop V/f Control (CL-V/f), Closed Loop Vector Control (CLV), Advanced Open Loop Vector Control for PM (AOLV/PM), and Closed Loop Vector Control for PM (CLV/PM): 400 Hz

  • V/f Control (V/f), Open Loop Vector Control (OLV), and Open Loop Vector Control for PM (OLV/PM): 590 Hz

Measures for Harmonics

DC reactor

Standard internal characteristics

Braking Device

Braking Transistor

External options

EMC Filter

EMC Filter

IEC 61800-3, C3

Factory option

  • Models 4xxxB: There is a category C3 EMC filter in the drive.

External options

Power Supply

Rated Voltage, Rated Frequency

  • Three-phase AC power supply 380 V to 480 V at 50/60 Hz

  • DC power supply 513 V to 679 V

Permitted Voltage Fluctuation

-15% to +10%

Permitted Frequency Fluctuation

±5%

Input Power (kVA)

HD

327

370

370

624

662

777

821

ND

370

465

465

701

734

870

923

1

The maximum applicable motor output complies with 380 V motor ratings as specified in Annex G of IEC 60947-4-1. The rated output current of the drive output amps must be equal to or more than the motor rated current.

2

The rated output capacity is calculated with a rated output voltage of 380 V.