Maximum Applicable Motor Output 1 (kW)
|
HD
|
11
|
15
|
18.5
|
22
|
30
|
37
|
45
|
|
ND
|
15
|
18.5
|
22
|
30
|
37
|
45
|
55
|
|
Input
|
Rated Input Current (A)
|
HD (AC)
|
30.6
|
41.3
|
50.5
|
43.1
|
58.3
|
71.5
|
86.5
|
|
HD (DC)
|
37.5
|
50.5
|
61.9
|
52.8
|
71.4
|
87.5
|
106.0
|
|
ND (AC)
|
41.3
|
50.5
|
59.7
|
58.3
|
71.5
|
86.5
|
105
|
|
ND (DC)
|
50.5
|
61.9
|
73.2
|
71.4
|
87.5
|
106.0
|
129
|
|
Output
|
Rated Output Capacity 2 (kVA)
|
HD
|
16
|
20
|
26
|
30
|
39
|
49
|
60
|
|
ND
|
20
|
25
|
29
|
39
|
49
|
59
|
68
|
|
Rated Output Current (A)
|
HD
|
24
|
31
|
39
|
45
|
60
|
75
|
91
|
|
ND
|
31
|
38
|
44
|
59.6
|
74.9
|
89.2
|
103
|
|
Overload Tolerance
|
-
HD: 150% of the rated output current for 60 seconds. The permitted frequency of overload is one time each 10 minutes.
-
ND: 110% of the rated output current for 60 seconds. The permitted frequency of overload is one time each 10 minutes.
Note:
Derating can be necessary for applications that start and stop frequently.
|
|
Carrier Frequency
|
HD: 8 kHz without derating the drive capacity.
ND: 2 kHz without derating the drive capacity.
Derate the drive capacity to use values to 15 kHz maximum.
|
|
Maximum Output Voltage
|
Three-phase 380 V to 480 V
Note:
The maximum output voltage is proportional to the input voltage.
|
|
Maximum Output Frequency
|
-
Advanced Open Loop Vector Control (AOLV) and EZ Open Loop Vector Control (EZOLV): 120 Hz
-
Closed Loop V/f Control (CL-V/f), Closed Loop Vector Control (CLV), Advanced Open Loop Vector Control for PM (AOLV/PM), and Closed Loop Vector Control for PM (CLV/PM): 400 Hz
-
V/f Control (V/f), Open Loop Vector Control (OLV), and Open Loop Vector Control for PM (OLV/PM): 590 Hz
|
|
Measures for Harmonics
|
DC reactor
|
External options
|
Standard internal characteristics
|
|
Braking Device
|
Braking Transistor
|
Standard internal characteristics
|
|
EMC Filter
|
EMC Filter
IEC 61800-3, C3
|
Factory option
|
|
Power Supply
|
Rated Voltage, Rated Frequency
|
|
|
Permitted Voltage Fluctuation
|
-15% to +10%
|
|
Permitted Frequency Fluctuation
|
±5%
|
|
Input Power (kVA)
|
HD
|
24
|
33
|
40
|
34
|
46
|
57
|
69
|
|
ND
|
33
|
40
|
48
|
46
|
57
|
69
|
84
|