Jump to main content

F1: Encoder Option Setup

F1 parameters set the operation of and protective function for the encoder option. Table 1 lists the setting parameters available for each option.

Refer to the instruction manual packaged with the encoder option for more information on how to install, wire, and set the encoder options.

Table 1. Encoder Option Setting Parameters

Setting Parameter

Encoder Option

PG-B3

PG-X3

PG-F3

PG-RT3

F1-01

x

x

x

-

F1-02

x

x

x

x

F1-03

x

x

x

x

F1-04

x

x

x

x

F1-05

x

x

x

x

F1-06

x

x

x

-

F1-08

x

x

x

x

F1-09

x

x

x

x

F1-10

x

x

x

x

F1-11

x

x

x

x

F1-12 1

x

x

-

-

F1-13 1

x

x

-

-

F1-14

x

x

x

x

F1-18

x

x

x

x

F1-19

x

x

x

x

F1-20

-

x

x

-

F1-21

x

x

-

-

F1-30

x

x

-

-

F1-31 2 3

x

x

-

-

F1-32 2 3

x

x

-

-

F1-33 1 2

x

x

-

-

F1-34 1 2

x

x

-

-

F1-35 2 3

x

x

-

-

F1-36 3

-

x

-

-

F1-37 2 3

x

x

-

-

F1-50

-

-

x

-

F1-51

-

-

x

-

F1-52

-

-

x

-

Number of options that you can install in a drive

2

2

1

1

 
1

Parameters set when A1-02 = 1 [CL-V/f].

2

Parameters to set an option connected to CN5-B. The drive recognizes the PG option installed to CN5-B as PG2.

3

When A1-02 = 3, 7 [Control Method Selection = CLV, CLV/PM], you can set the parameters for PG2 without setting H1-xx = 16 [Terminal Sx Function Selection = Motor 2 Selection].

The drive recognizes the PG option installed to CN5-B as PG2. You can use it as a function block (PG CH2, PGP ZP CH2) in DriveWorksEZ. These are the restrictions:

  • Install the PG option for motor control (PG1) to CN5-C.

  • The drive detects hardware disconnection of CN5-C (PG1) and CN5-B (PG2), but does not detect Z-phase disconnection of CN5-B (PG2).

  • Do not set H1-xx = 16. When H1-xx = 16, PG2 acts as a motor speed detector.