b3-04
|
V/f Gain during Speed Search
|
%
|
100
|
100
|
100
|
100
|
100
|
100
|
100
|
100
|
|
b3-06
|
Speed Estimation Current Level 1
|
-
|
0.5
|
0.5
|
0.5
|
0.5
|
0.5
|
0.5
|
0.5
|
0.5
|
|
b3-07
|
Speed Estimation Current Level 2
|
-
|
1.0
|
1.0
|
1.0
|
1.0
|
1.0
|
1.0
|
1.0
|
1.0
|
|
b3-08
|
Speed Estimation ACR P Gain
|
-
|
0.5
|
0.5
|
0.5
|
0.5
|
0.5
|
0.5
|
0.5
|
0.5
|
|
b3-26
|
Direction Determination Level
|
-
|
1000
|
1000
|
1000
|
1000
|
1000
|
1000
|
1000
|
1000
|
|
b8-03
|
Energy Saving Filter Time
|
s
|
0.50
|
0.50
|
0.50
|
0.50
|
0.50
|
0.50
|
0.50
|
0.50
|
|
b8-04
|
Energy Saving Coefficient Value
|
-
|
576.4
|
447.4
|
447.4
|
338.8
|
338.8
|
313.6
|
313.6
|
265.7
|
|
C5-17
(C5-37)
|
Motor Inertia
|
kgm2
|
0.0015
|
0.0028
|
0.0028
|
0.0068
|
0.0068
|
0.0088
|
0.0088
|
0.0158
|
|
C6-02
|
Carrier Frequency Selection
|
-
|
1
|
7
|
1
|
7
|
1
|
7
|
1
|
7
|
|
E2-01
(E4-01)
|
Motor Rated Current (FLA)
|
A
|
1
|
1.6
|
1.6
|
3.1
|
3.1
|
4.2
|
4.2
|
5.7
|
|
E2-02
(E4-02)
|
Motor Rated Slip
|
Hz
|
2.9
|
2.6
|
2.6
|
2.5
|
2.5
|
3
|
3
|
2.7
|
|
E2-03
(E4-03)
|
Motor No-Load Current
|
A
|
0.6
|
0.8
|
0.8
|
1.4
|
1.4
|
1.5
|
1.5
|
1.9
|
|
E2-05
(E4-05)
|
Motor Line-to-Line Resistance
|
Ω/mΩ 2
|
38.198
|
22.459
|
22.459
|
10.1
|
10.1
|
6.495
|
6.495
|
4.360
|
|
E2-06
(E4-06)
|
Motor Leakage Inductance
|
%
|
18.2
|
14.3
|
14.3
|
18.3
|
18.3
|
18.7
|
18.7
|
19
|
|
E2-10
(E4-10)
|
Motor Iron Loss
|
W
|
14
|
26
|
26
|
53
|
53
|
77
|
77
|
105
|
|
E5-01
|
PM Motor Code Selection
|
-
|
1232
|
1232
|
1233
|
1233
|
1235
|
1235
|
1236
|
1236
|
|
L2-02
|
Power Loss Ride Through Time
|
s
|
0.1
|
0.1
|
0.2
|
0.2
|
0.3
|
0.3
|
0.5
|
0.5
|
|
L2-03
|
Minimum Baseblock Time
|
s
|
0.2
|
0.3
|
0.3
|
0.4
|
0.4
|
0.5
|
0.5
|
0.5
|
|
L2-04
|
Powerloss V/f Recovery Ramp Time
|
s
|
0.3
|
0.3
|
0.3
|
0.3
|
0.3
|
0.3
|
0.3
|
0.3
|
|
L2-05
|
Undervoltage Detection Lvl (Uv1)
|
-
|
380
|
380
|
380
|
380
|
380
|
380
|
380
|
380
|
|
L3-24
|
Motor Accel Time @ Rated Torque
|
s
|
0.178
|
0.142
|
0.142
|
0.166
|
0.166
|
0.145
|
0.145
|
0.145
|
|
L8-02
|
Overheat Alarm Level
|
°C
|
100
|
100
|
105
|
105
|
112
|
112
|
100
|
100
|
|
L8-09
|
Output Ground Fault Detection
|
-
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
L8-38
|
Carrier Frequency Reduction
|
-
|
2
|
2
|
2
|
2
|
2
|
2
|
2
|
2
|
|
n1-01
|
Hunting Prevention Selection
|
-
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
1
|
|
n1-03
|
Hunting Prevention Time Constant
|
ms
|
10
|
10
|
10
|
10
|
10
|
10
|
10
|
10
|
|
n1-16
|
Hunting Prevention High Fc Gain
|
-
|
0.50
|
0.50
|
0.50
|
0.50
|
0.50
|
0.50
|
0.50
|
0.50
|
|
n5-02
|
Motor Inertia Acceleration Time
|
s
|
0.178
|
0.142
|
0.142
|
0.166
|
0.166
|
0.145
|
0.145
|
0.145
|