Area of Use
|
Indoors
|
|
Power Supply
|
Overvoltage Category III (IEC60664)
|
|
Surrounding Air Temperature
|
-10 °C to +35 °C (14 °F to 95 °F)
-
Drive reliability is better in environments where the temperature does not increase or decrease quickly.
-
When you install the drive in an enclosure, use a cooling fan or air conditioner to keep the internal air temperature in the permitted range.
-
Do not let the drive freeze.
-
You can use finless-type drives at a maximum of +50 °C (122 °F) when you derate the output current. 1
|
|
Humidity
|
95%RH or less
Do not let condensation form on the drive.
|
|
Storage Temperature
|
-20 °C to +70 °C (-4 °F to +158 °F) (short-term temperature during transportation)
|
|
Surrounding Area
|
Pollution degree 2 or less (IEC 60664-1)
Install the drive in an area without:
-
Oil mist, corrosive or flammable gas, or dust
-
Metal powder, oil, water, or other unwanted materials
-
Radioactive or flammable materials.
-
Harmful gas or fluids
-
Salt
-
Direct sunlight
Keep wood and other flammable materials away from the drive.
|
|
Altitude
|
1000 m (3281 ft) Maximum
Note:
Derate the output current by 1% for each 100 m (328 ft) to install the drive in altitudes between 1000 m to 4000 m (3281 ft to 13123 ft).
It is not necessary to derate the rated voltage in these conditions:
-
When you install the drive at 2000 m (6562 ft) or lower
-
When you install the drive between 2000 m to 4000 m (6562 ft to 13123 ft) and ground the neutral point on the power supply.
Contact Yaskawa or your nearest sales representative if you will not ground the neutral point.
|
|
Vibration
|
-
10 Hz to 20 Hz: 1 G (9.8 m/s2, 32.15 ft/s2)
-
20 Hz to 55 Hz: 0.6 G (5.9 m/s2, 19.36 ft/s2)
|
|
Installation Orientation
|
Install the drive vertically for sufficient airflow to cool the drive.
|