YASKAWA AC Drive GA700 High Performance Type Technical Manual
Table 1 , Table 2, and Table 3 give the rated output current values.
Rated output current values are applicable for drives that operate at standard specifications.
Derate the output current in applications that:
Increase the carrier frequency
Have high ambient temperature
Install drives side-by-side.
Use C6-01 [Normal / Heavy Duty Selection] to select Normal Duty rating (ND) or Heavy Duty rating (HD).
Model
Heavy Duty Rating (HD)
[C6-01 = 0]
Normal Duty Rating (ND)
[C6-01 = 1]
(Default)
Maximum Applicable Motor Output
kW (HP)
Rated Output Current
A
B001
0.1 (1/6)
0.8
0.2 (1/6)
1.2
B002
0.2 (1/4)
1.6
0.4 (1/4)
1.9
B004
0.4 (1/2)
3.0
0.75 (3/4)
3.5
B006
0.75 (1)
5.0
1.1 (1.5)
6.0
B010
1.5 (2)
8.0
2.2 (3)
9.6
B012
11.0
3.0 (3)
12.2
B018
3.7 (5)
17.6
-
2001
2002
2004
2006
2008
6.9
2010
2012
3.0 (4)
2018
14.0
17.5
2021
5.5 (7.5)
21.0
2030
25.0
7.5 (10)
30.0
2042
33.0
11.0 (15)
42.0
2056
47.0
15.0 (20)
56.0
2070
60.0
18.5 (25)
70.0
2082
75.0
22.0 (30)
82.0
4001
0.2 (1/2)
4002
0.4 (3/4)
1.8
2.1
4004
0.75 (2)
3.4
4.1
4005
1.5 (3)
4.8
5.4
4007
5.6
7.1
4009
7.3
8.9
4012
9.2
11.9
4018
5.5 (10)
14.8
4023
18.0
23.4
4031
24.0
31.0
4038
38.0
4044
39.0
44.0
4060
45.0
30.0 (40)