Table 1. Drive Watt Loss (HD, Fc = 2 kHz) Model The rated output current A Carrier Frequency kHz Interior Unit Loss W Cooling Fin Loss W Total Loss W 4001 1.2 2 8 7 15 4002 1.8 2 10 10 20 4004 3.4 2 13 21 34 4005 4.8 2 15 29 44 4007 5.6 2 16 33 49 4009 7.3 2 21 45 66 4012 9.2 2 27 60 87 4018 14.8 2 48 126 174 4023 18 2 53 152 205 4031 24 2 68 191 259 4038 31 2 81 256 337 4044 1 39 2 109 338 447 4060 1 45 2 114 328 442 Table 2. Drive Watt Loss (HD, Fc = Default Setting) Model The rated output current A Carrier Frequency kHz Interior Unit Loss W Cooling Fin Loss W Total Loss W 4001 1.2 8 9 11 20 4002 1.8 8 11 16 27 4004 3.4 8 15 31 46 4005 4.8 8 18 42 60 4007 5.6 8 18 49 67 4009 7.3 8 25 65 90 4012 9.2 8 32 85 117 4018 14.8 8 55 166 221 4023 18 8 61 200 261 4031 24 8 79 255 334 4038 31 8 95 338 433 4044 1 39 8 127 442 569 4060 1 45 8 135 446 581 Table 3. Drive Watt Loss (ND) Model The rated output current A Carrier Frequency kHz Interior Unit Loss W Cooling Fin Loss W Total Loss W 4001 1.2 2 8 7 15 4002 2.1 2 13 12 25 4004 4.1 2 14 24 38 4005 5.4 2 16 32 48 4007 7.1 2 20 44 64 4009 8.9 2 28 58 86 4012 11.9 2 39 83 122 4018 17.5 2 52 155 207 4023 23.4 2 86 236 322 4031 31 2 101 284 385 4038 38 2 108 341 449 40441 44 2 137 417 554 4060 1 60 2 176 490 666 1 There are not finless-type 4044 or 4060 models.