• When you use the drive keypad

    Set U4-08 [Heatsink Temperature] to show the drive heatsink temperature.

    Figure 1. U4-08 [Heatsink Temperature] (When the heatsink plate is 89 °C)
  • When you use a Multi-function Analog Monitor Output

    When you use terminal AM, set the parameters as shown in Table 1.

    Table 1. MFAO Settings

    Parameter

    Name

    Setting

    H4-01

    Terminal AM Analog Output Select

    408 (U4-08)

    H4-02

    Terminal AM Analog Output Gain

    100.0%

    H4-03

    Terminal AM Analog Output Bias

    0.0%

    Figure 2. Heatsink Plate Temperature Output on MFAO
    Note:
    • The accuracy is ±5 °C (41 °F) for heatsink plate temperatures between 50 °C to 100 °C (122 °F to 212 °F).

    • The installation environment has an effect on the temperature.