Keep the drive heatsink plate temperature lower than the maximum temperature even when the ambient temperature is 50 °C (122 °F). Refer to Table 1 for the maximum temperature of the heatsink plate. When you operate the drive in an ambient temperature of 35 °C (95 °F) or higher, refer to Derating Depending on Ambient Temperature and derate the drive.

Table 1. Maximum Temperature of the Heatsink Plate

Model

Maximum Temperature of the Heatsink Plate

B001 - B012

90 °C (194 °F)

2001 - 2021

90 °C (194 °F)

2030 - 2070

80 °C (176 °F)

4001 - 4012

90 °C (194 °F)

4018 - 4038

80 °C (176 °F)

Refer to Single-Phase 200 V Class, Three-Phase 200 V Class, and Three-Phase 400 V Class for the drive watt loss data.

Refer to Monitor Heatsink Plate Temperature to monitor drive heatsink plate temperature.