No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
b2-04
(018C)
|
DC Inject Braking Time at Stop
|
   
Sets the DC Injection Braking Time at stop.
|
Determined by A1-02
(0.00 - 10.00 s)
|
This function fully stops a motor with a large inertia during deceleration and will not let the inertia continue to rotate the motor.
Set this parameter to 0.00 to disable the function.
When a longer time is required to stop the motor, increase the value.