The d4 parameters set the Frequency Reference Hold function and Up/Down and Up/Down 2 commands.

  • Frequency Reference Hold Function Command: This acceleration/deceleration ramp hold command uses an MFDI to momentarily stop the acceleration/deceleration of the motor, and continues to operate the motor at the output frequency at which the command reference was input. Turn OFF the acceleration/deceleration ramp hold command to continue acceleration/deceleration.

    With a crane for example, use the function and a 2-stage push button to stop acceleration and operate at low speed with one of the output frequencies.

  • Up/Down command: The Up/Down command is a function to activate and deactivate an MFDI to increase and decrease the frequency reference. The Up/Down command overrides frequency references from the analog input terminal, pulse train input terminal, and keypad.