No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
b3-14
(019E)
|
Bi-directional Speed Search
|
   
Sets the direction of Speed Search to the direction of the frequency reference or in the motor rotation direction as detected by the drive.
|
Determined by A1-02 and b3-24
(0, 1)
|
Note:
-
When E9-01 = 0 [Motor Type Selection = Induction (IM)] and A1-02 = 0, 2, or 8 [Control Method Selection = V/f, OLV, or EZOLV], the default settings change when the setting of b3-24 [Speed Search Method Selection] changes.
-
When E9-01 = 1 or 2 [Permanent Magnet (PM), Synchronous Reluctance (SynRM)] and A1-02 = 0 or 8 [V/f, EZOLV], refer to Parameters that Change from the Default Settings with A1-02 [Control Method Selection].
When you set A1-02, b3-24, and E9-01, set b3-14.
- 0
- Disabled
-
The drive uses the frequency reference to detect the direction of motor rotation.
- 1
- Enabled
-
The drive detects the direction of motor rotation during Speed Search.