No.

(Hex.)

Name

Description

Default

(Range)

b3-32

(0BC1)

Expert

Spd Search Current Complete Lvl

Sets the current level that completes Speed Search.

1.20

(0.00 - 1.49)

The Current Detection Speed Search gradually decreases the output frequency to search for the motor speed when the output current is equal to or less than Speed Search Current Complete Level.

Set this parameter as a ratio of E2-03 [Motor No-Load Current]. The setting is a ratio with respect to 30% of the motor rated current when E2-03E2-01 [Motor Rated Current (FLA)] × 0.3.

Note:

When A1-02 = 8 [Control Method Selection = EZOLV], the setting is a ratio with respect to E9-06 [Motor Rated Current (FLA)] × 0.5.