b8-19

(0B40)

Expert

E-Save Search Frequency

Sets the frequency of Energy-saving control search operations. Usually it is not necessary to change this setting.

Determined by A1-02

(10 - 300 Hz)

Note:
  • If low inertia causes vibration in the machine, increase the setting value in 10 Hz increments and check the response. If A1-02 = 8 [Control Method Selection = EZOLV], increase the setting value in 1 Hz increments.

  • To make the motor more efficient, decrease the setting value in 1 Hz increments until the point immediately before machine vibration starts to occur.