No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
C5-12
(0386)
|
Integral Operation @ Accel/Decel
|
   
Sets ASR integral operation during acceleration and deceleration.
|
0
(0, 1)
|
Set this parameter to 1 to keep the motor speed near the frequency reference during operation and acceleration/deceleration.
Note:
-
When A1-02 = 0 [Control Method Selection = V/f], set H6-01 = 3 [Terminal RP Pulse Train Function = Speed Feedback (V/F Control)] to enable this parameter.
-
If you enable integral control, overshoot or undershoot can occur when acceleration or deceleration complete. If there are problems with overshooting and undershooting, set this parameter to 0.
- 0
- Disabled
-
The drive will not enable integral operation during acceleration or deceleration. The drive always enables integral operation during constant speed.
- 1
- Enabled
-
Integral operation is always enabled.