YASKAWA AC Drive GA700 High Performance Type Technical Manual
This section gives information about the procedures to set these examples:
Multi-Step Speed 6 (6 types of frequency references)
When you set the voltage input of analog inputs from terminals A1 and A2 to 0 V to 10 V (Lower Limit at 0)
Procedure
Configuration Parameter
Task Contents
1
Reference 1
Sets b1-01 = 1 [Frequency Reference Selection 1 = Analog Input].
Sets H3-02 = 0 [Terminal A1 Function Selection = Frequency Reference].
Sets H3-01 = 0 [Terminal A1 Signal Level Select = 0 V to 10 V (Lower Limit at 0)].
2
Reference 2
Sets H3-10 = 2 [Terminal A2 Function Selection = Auxiliary Frequency Reference 1].
Sets H3-09 = 0 [Terminal A2 Signal Level Select = 0 V to 10 V (Lower Limit at 0)].
3
Signal type of analog input
Set DIP switch S1 on the control circuit board to the V-side (voltage) to set terminal A2 only for voltage input.
Set this before you energize the drive.
4
Reference 3
Sets the value of d1-03 [Reference 3].
5
Reference 4
Sets the value of d1-04 [Reference 4].
6
Reference 5
Sets the value of d1-05 [Reference 5].
7
Jog Reference
Sets d1-17 [Jog Reference] to the jog speed.
8
External digital input (3 inputs)
Set the Multi-Step Speed Reference 1 to 3 [H1-xx = 3, 4, 5] to one of the MFDI terminals S1 to S7.
9
JOG command
Set the Jog Reference Selection [H1-xx = 6] to one of the MFDI terminals S1 to S7.
This section is the procedure to set the 17-step speeds (17 types of frequency references) without an analog input.
Analog reference
Sets H3-02 = F [Terminal A1 Function Selection = Not Used], and disables the analog reference.
Sets H3-10 = F [Terminal A2 Function Selection = Not Used], and disables the analog reference.
Reference 2 to 16
Sets the values of d1-02 to d1-16 [Reference 2 to 16].
External digital input (4 inputs)
Set Multi-Step Speed Reference 1 to 4 [H1-xx = 3, 4, 5, 32] to one of the MFDI terminals S1 to S7.
Refer to Table 1 and Figure 1 for information about multi-step speed reference combinations. The selected frequency reference changes when the combination of digital input signals from an external source changes.
Related Parameters
Multi-Step Speed Reference 1
H1-xx = 3
Multi-Step Speed Reference 2
H1-xx = 4
Multi-Step Speed Reference 3
H1-xx = 5
Multi-Step Speed Reference 4
H1-xx = 32
H1-xx = 6
Reference 1 (set in b1-01)
OFF
Reference 2 (d1-02 or terminals A1, A2)
ON
Reference 3 (d1-03 or terminals A1, A2)
Reference 4 (d1-04)
Reference 5 (d1-05)
Reference 6 (d1-06)
Reference 7 (d1-07)
Reference 8 (d1-08)
Reference 9 (d1-09)
Reference 10 (d1-10)
Reference 11 (d1-11)
Reference 12 (d1-12)
Reference 13 (d1-13)
Reference 14 (d1-14)
Reference 15 (d1-15)
Reference 16 (d1-16)
Jog Reference (d1-17)1
-