YASKAWA AC Drive GA700 High Performance Type Technical Manual
No.
(Hex.)
Name
Description
Default
(Range)
d4-03
(02AA)
RUN
Up/Down 2 Bias Step Frequency
Sets the bias that the Up/Down 2 function adds to or subtracts from the frequency reference.
0.00 Hz
(0.00 - 99.99 Hz)
The operation is different for different setting values:
Setting d4-03 = 0.00 Hz
When the Up/Down 2 Command [H1-xx = 75, 76] is active, the drive uses the accel/decel times set in d4-04 [Up/Down 2 Ramp Selection] to increase or decrease the bias value.
Setting d4-03 ≠ 0.00 Hz
When the Up/Down 2 Command [H1-xx = 75, 76] is active, the drive increases or decreases the bias in steps for the value set in d4-03. The drive uses the acceleration and deceleration times set in d4-04.