E2-07: Motor Saturation Coefficient 1

No.

(Hex.)

Name

Description

Default

(Range)

E2-07

(0314)

Motor Saturation Coefficient 1

Sets the motor iron-core saturation coefficient at 50% of the magnetic flux.

0.50

(0.00 - 0.50)

The drive uses this coefficient when it operates with constant output. The drive uses this coefficient when it operates the motor in the constant output range.