No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
E4-05
(0325)
|
Motor 2 Line-to-Line Resistance
|
   
Sets the line-to-line resistance for the motor 2 stator windings.
|
Determined by o2-04, C6-01
(0.000 - 65.000 Ω)
|
Note:
This value is the line-to-line resistance for motor 2. Do not set this parameter with the resistance per phase.
Auto-Tuning automatically sets this parameter. If you cannot do Auto-Tuning, use the test report from the motor manufacturer to configure the settings. To calculate the motor line-to-line resistance, use the information shown on the motor nameplate with one of these formulas:
-
E-type insulation: [the resistance value (Ω) shown on the test report at 75 °C] × 0.822
-
B-type insulation: [the resistance value (Ω) shown on the test report at 75 °C] × 0.822
-
F-type insulation: [the resistance value (Ω) shown on the test report at 115 °C] × 0.728