E5-09: PM Back-EMF Vpeak (mV/(rad/s))

No.

(Hex.)

Name

Description

Default

(Range)

E5-09

(0331)

PM Back-EMF Vpeak (mV/(rad/s))

Sets the peak value of PM motor induced voltage.

0.0 mV/(rad/sec)

(0.0 - 2000.0 mV/(rad/s))

Set this parameter when you use an IPM motor (SSR1-Series).

PM motor Auto-Tuning automatically sets this parameter to the value of [Back-EMF Voltage Constant (Ke)].

When E5-01 = FFFF, only set E5-09 or E5-24 [PM Back-EMF L-L Vrms (mV/rpm)] as the induced voltage constant.

Note:

When you set this parameter, also set E5-24 = 0.0. The drive will detect oPE08 [Parameter Selection Error] in these conditions:

  • E5-09 = 0.0 and E5-24 = 0.0

  • E5-09 ≠ 0.0 and E5-24 ≠ 0.0