No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
E9-10
(11ED)
|
Motor Line-to-Line Resistance
|
   
Sets the line-to-line resistance for the motor stator windings.
|
Determined by o2-04
(0.000 - 65.000 Ω)
|
Note:
This value is the motor line-to-line resistance. Do not set this parameter with the resistance per phase.
Stationary Auto-Tuning automatically sets this parameter. If you cannot do Stationary Auto-Tuning, use the test report from the motor manufacturer. Use one of these formulas to calculate the motor line-to-line resistance:
-
E-type insulation: [the resistance value (Ω) shown on the test report at 75 °C] × 0.822
-
B-type insulation: [the resistance value (Ω) shown on the test report at 75 °C] × 0.822
-
F-type insulation: [the resistance value (Ω) shown on the test report at 115 °C] × 0.728