n1-05
(0530)
Expert
|
Hunting Prevent Gain in Reverse
|
   
Sets the performance of the hunting prevention function. This parameter adjusts Reverse run. Usually it is not necessary to change this parameter.
|
0.00
(0.00 - 2.50)
|
Note:
When you set n1-05 = 0, the value set in n1-02 [Hunting Prevention Gain Setting] is effective when the motor rotates in reverse.
Adjust this parameter in these conditions:
-
When n1-01 = 1 [Hunting Prevention Selection = Enabled (Normal), if oscillation occurs when you operate a motor with a light load, increase the setting value in 0.1-unit increments.
-
When n1-01 = 2, if the motor stalls, decrease the setting value in 0.1-unit increments.