L3-36: Current Suppression Gain@Accel

No.

(Hex.)

Name

Description

Default

(Range)

L3-36

(11D0)

Current Suppression Gain@Accel

Sets the gain to suppress current and motor speed hunting during operation when L3-01 = 3 [Stall Prevention during Accel = Current Limit Method]. Usually it is not necessary to change this setting.

Determined by A1-02

(0.0 - 100.0)

If there is vibration in the output current during acceleration, increase the setting value.

Note:

Set L3-01 = 3 [Stall Prevention during Accel = Current Limit Method] to enable this function.