Jump to main content

L5-08: Fault Reset Enable Select Grp2

No.

(Hex.)

Name

Description

Default

(Range)

L5-08

(0B2B)

Fault Reset Enable Select Grp2

Use these 4 digits to set the Auto Restart function for Uv1, ov, oH1, and GF. From left to right, the digits set Uv1, ov, oH1, and GF, in order.

1111

(0000 - 1111)

0000
Disabled
 
0001
Enabled (—/–/—/GF)
 
0010
Enabled (—/–/oH1/–)
 
0011
Enabled (—/–/oH1/GF)
 
0100
Enabled (—/ov/—/–)
 
0101
Enabled (—/ov/—/GF)
 
0110
Enabled (—/ov/oH1/–)
 
0111
Enabled (—/ov/oH1/GF)
 
1000
Enabled (Uv1/–/—/–)
 
1001
Enabled (Uv1/–/—/GF)
 
1010
Enabled (Uv1/–/oH1/–)
 
1011
Enabled (Uv1/–/oH1/GF)
 
1100
Enabled (Uv1/ov/—/–)
 
1101
Enabled (Uv1/ov/—/GF)
 
1110
Enabled (Uv1/ov/oH1/–)
 
1111
Enabled (Uv1/ov/oH1/GF)
 
Figure 1. Setting Digits and Fault Code