L6-08

(0468)

Mechanical Fatigue Detect Select

Sets the speed where the drive detects mechanical deterioration and how the drive operates (operation status) after detection.

0

(0 - 8)

The drive detects mechanical weakening through overtorque or undertorque as specified by the conditions set in L6-08 to L6-11 [Mechanical Deterioration Detection Settings Parameters]. Set overtorque/undertorque detection conditions in L6-01 to L6-03 [Torque Detection 1 Settings Parameters]. The drive disables the operation selection set in L6-01 [Torque Detection Selection 1].

0
Disabled

The drive does not detect mechanical weakening.

1
oL5 @ Speed > L6-09 - Alarm

When the speed (signed) ≥ L6-09 [Mech Fatigue Detect Speed Level], the drive detects mechanical weakening. The drive will detect oL5 [Mechanical Weakening Detection 1] and continue operation.

2
oL5 @ |Speed| > L6-09 - Alarm

When the speed (absolute value) ≥ L6-09, the drive detects mechanical weakening. The drive will detect oL5 and continue operation.

3
oL5 @ Speed > L6-09 - Fault

When the speed (signed) ≥ L6-09, the drive detects mechanical weakening. The drive will detect oL5 and stop operation.

4
oL5 @ |Speed| > L6-09 - Fault

When the speed (absolute value) ≥ L6-09, the drive detects mechanical weakening. The drive will detect oL5 and stop operation.

5
UL5 @ Speed < L6-09 - Alarm

When the speed (signed) ≤ L6-09, the drive detects mechanical weakening. The drive will detect UL5 [Mechanical Weakening Detection 2] and continue operation.

6
UL5 @ |Speed| < L6-09 - Alarm

When the speed (absolute value) ≤ L6-09, the drive detects mechanical weakening. The drive will detect UL5 and continue operation.

7
UL5 @ Speed < L6-09 - Fault

When the speed (signed) ≤ L6-09, the drive detects mechanical weakening. The drive will detect UL5 and stop operation.

8
UL5 @ |Speed| < L6-09 - Fault

When the speed (absolute value) ≤ L6-09, the drive detects mechanical weakening. The drive will detect UL5 and stop operation.