Jump to main content

H2-32: Comparator 1 Filter Time

No.

(Hex.)

Name

Description

Default

(Range)

H2-32

(159A)

Comparator 1 Filter Time

Sets the time constant that is applied to the primary delay filter used for the analog output of the monitor selected with H2-20 [Comparator 1 Monitor Selection].

0.0s

(0.0 - 10.0 s)

Note:

For information on the comparator function, refer to 66: Comparator1 and 67: Comparator2.