YASKAWA AC Drive GA700 High Performance Type Technical Manual
No.
(Hex.)
Name
Description
Default
(Range)
n7-01
(3111)
Expert
Damping Gain for Low Frequency
Sets the oscillation suppression gain for the low speed range.
1.0
(0.1 - 10.0)
If oscillation occurs in the low speed range, increase the acceleration time or increase the setting value in 0.5-unit increments.
To get starting torque with the setting for C4-01 [Torque Compensation Gain], decrease the setting value in 0.3-unit increments.