Jump to main content

n7-17: Resistance TemperatureCorrection

No.

(Hex.)

Name

Description

Default

(Range)

n7-17

(3122)

Resistance TemperatureCorrection

Sets the function to adjust for changes in the motor resistance value caused by changes in the temperature.

1

(0 to 2)

0
Invalid
 
1
Valid (Only 1 time)
 
2
Valid (Every time)
 
Note:
  • For settings 1 and 2, the adjustment time can cause a delay before startup.

  • For settings 1 and 2, the drive can set the line-to-line resistance value of E9-10 [Motor Line-to-Line Resistance].

  • When the temperature will change at startup, use setting 2.

  • To decrease the startup time, set this parameter to 0, then do line-to-line resistance tuning.

  • If you will start from coasting, set this parameter to 0, then do line-to-line resistance tuning.