Jump to main content

n8-02: Pole Alignment Current Level

No.

(Hex.)

Name

Description

Default

(Range)

n8-02

(0541)

Expert

Pole Alignment Current Level

Sets the current at the time of polar attraction as a percentage where E5-03 [motor rated current] is 100%. Usually it is not necessary to change this setting.

80%

(0 - 150%)

The drive uses the polar pull-in current to attract the rotor after it detects the initial rotor position. When you increase the value of n8-02, the starting torque also increases.

  • If the motor does not track correctly at the time of the polar attraction, increase the value in 10% increments.

  • If the motor oscillates at the time of the polar attraction, decrease the value in 10% increments.