Jump to main content

n8-54: Voltage Error Compensation Time

No.

(Hex.)

Name

Description

Default

(Range)

n8-54

(056D)

Expert

Voltage Error Compensation Time

Sets the time constant that the drive uses when adjusting for voltage errors.

1.00 s

(0.00 - 10.00 s)

Adjust this parameter in these conditions:

  • If oscillation occurs at the time of start up, increase the setting value.

  • If hunting occurs when operating at low speed, increase the setting value.

  • If fast changes in the load cause hunting, increase the setting value in 0.1-unit increments. If you cannot stop hunting, set n8-51 [Pull-in Current @ Acceleration] to 0% and set n8-54 to 0.00 s, and disable compensation for voltage errors.