No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
H3-13
(041B)
|
Analog Input FilterTime Constant
|
   
Sets the time constant for primary delay filters on MFAI terminals.
|
0.03 s
(0.00 - 2.00 s)
|
Apply the primary delay filter to the analog input to enable an analog input signal without the use of high-frequency noise components. An analog input filter prevents irregular drive control. Drive operation becomes more stable as the programmed time becomes longer, but it also becomes less responsive to quickly changing analog signals.