Setting Value
|
Function
|
Description
|
|
1
|
Frequency Gain
|
   
The drive multiplies the analog frequency reference with the input value from the MFAI set with this function.
|
Example: When you set frequency gain for terminal A2
-
H3-10 = 1 [Terminal A2 Function Selection = Frequency Gain]
-
A 50% frequency gain is input to terminal A2
-
A frequency reference of 80% is input from terminal A1
The calculated frequency reference is 40% of the maximum output frequency.