No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
A1-04
(0104)
|
Password
|
   
Entry point for the password set in A1-05 [Password Setting]. The user can view the settings of parameters that are locked without entering the password. Enter the correct password in this parameter to change parameter settings.
|
0000
(0000 - 9999)
|
If the password entered in A1-04 does not agree with the password setting in A1-05, you cannot change these parameters:
-
A1-01 [Access Level Selection]
-
A1-02 [Control Method Selection]
-
A1-03 [Initialize Parameters]
-
A1-06 [Application Preset]
-
A1-07 [DriveWorksEZ Function Selection]
-
A2-01 to A2-32 [User Parameter 1 to 32]
To lock parameter settings after making changes without changing the password, enter the incorrect password in A1-04 and push
.