A1-02
|
Control method selection
|
0: V/f Control
|
|
b1-01
|
Frequency Reference Selection 1
|
0: Keypad
|
|
C1-01
|
Acceleration Time 1
|
3.0 s
|
|
C1-02
|
Deceleration Time 1
|
3.0 s
|
|
C6-01
|
Normal / Heavy Duty Selection
|
0: Heavy Duty Rating
|
|
C6-02
|
Carrier Frequency Selection
|
2: 5 kHz
|
|
d1-01
|
Reference 1
|
6.00 Hz
|
|
d1-02
|
Reference 2
|
30.00 Hz
|
|
d1-03
|
Reference 3
|
60.00 Hz
|
|
H1-05
|
Terminal S5 Function Selection
|
3: Multi-Step Speed Reference 1
|
|
H1-06
|
Terminal S6 Function Selection
|
4: Multi-Step Speed Reference 2
|
|
H2-01
|
Terminal M1-M2 Function Selection
|
37: During Frequency Output
|
|
H2-02
|
Terminal M3-M4 Function Selection
|
37: During Frequency Output
|
|
H3-06
|
Terminal A3 Function Selection
|
1F: Not Used
|
|
L3-04
|
Stall Prevention during Decel
|
0: Disabled
|
|
L8-05
|
Input Phase Loss Protection Sel
|
1: Enabled
|
|
L8-07
|
Output Phase Loss Protection Sel
|
1: Fault when one phase is lost
|
|
L8-38
|
Carrier Frequency Reduction
|
1: Enabled below 6 Hz
|
|
L8-41
|
High Current Alarm Selection
|
1: Enabled
|