You can set four different acceleration and deceleration time pairs in the drive. When you activate and deactivate H1-xx = 7, 16, 1A [MFDI Function Select = Accel/Decel Time Selection 1, Motor 2 Selection, Accel/Decel Time Selection 2], you can switch acceleration and deceleration times during run.
Acceleration time parameters always set the time to accelerate from 0 Hz to E1-04 [Maximum Output Frequency]. Deceleration time parameters always set the time to decelerate from E1-04 to 0 Hz.
C1-01 [Acceleration Time 1] and C1-02 [Deceleration Time 1] are the default active accel/decel settings.
|
Parameter
|
Range
|
|
C1-01 [Acceleration Time 1]
|
0.0 to 6000.0 s
|
|
C1-02 [Deceleration Time 1]
|
|
C1-03 [Acceleration Time 2]
|
|
C1-04 [Deceleration Time 2]
|
|
C1-05 [Acceleration Time 3]
|
|
C1-06 [Deceleration Time 3]
|
|
C1-07 [Acceleration Time 4]
|
|
C1-08 [Deceleration Time 4]
|
Note:
The setting range for acceleration and deceleration times is 0.00 to 600.00 s when C1-10 = 0 [Accel/Decel Time Setting Units = 0.01 s (0.00 to 600.00 s)].