F1-18
(03AD)
|
Deviation 3 Detection Selection
|
       
Sets the number of rotations necessary to detect conditions that invert the torque reference and rate of acceleration and cause dv3 [Inversion Detection].
|
10
(0 - 10)
|
When the drive detects these two conditions at the same time for the number of times set in F1-18, the drive will detect dv3.
-
The torque reference and acceleration are in opposite directions. For example, torque reference is in forward run and the acceleration is in a negative direction.
-
The difference between the speed reference and the actual motor speed is more than 30%.
Note:
-
Reference the setting value for E5-11 [Encoder Z-Pulse Offset] and the δθ value found on the motor nameplate. A usual cause for a dv3 fault is an incorrect E5-11 setting.
-