No.

(Hex.)

Name

Description

Default

(Range)

A2-01 to A2-32

(0106 - 0125)

User Parameters 1 to 32

You can select a maximum of 32 parameters for the drive and set them to parameters A2-01 to A2- 32. The [User Parameters] section of the keypad main menu shows the set parameters. You can immediately access these set parameters.

Parameters in General-Purpose Setup Mode

(Determined by A1-06)

Note:
  • When the A1-06 [Application Preset] value changes, the settings for A2-01 to A2-32 change.

  • You must set A1-01 = 1 [Access Level Selection = User Parameters] to access parameters A2-01 to A2-32.

  • When A1-07 = 1 or 2 [DriveWorksEZ Function Selection = DWEZ Enabled or Enabled/Disabled wDigital Input], the drive saves qx-xx [DriveWorksEZ Parameters] to A2-01 to A2-32.

The drive saves these parameters to A2-01 to A2-32.

  • The drive saves a maximum of 32 parameters.

    Note:

    Set A1-01 = 2 [Advanced Level] or A1-01 = 3 [Expert Level] to save the necessary parameters.

  • The drive automatically saves changed parameters to A2-17 to A2-32.

    Note:

    Set A2-33 = 1 [User Parameter Auto Selection = Enabled: Auto Save Recent Parms].