No. (Hex.) Name Description Default (Range) F6-20 (036B) MECHATROLINK Station Address Sets the station address for MECHATROLINK communication. Restart the drive after you change the parameter setting. 0021h (MECHATROLINK-II: 0020h - 003Fh, MECHATROLINK-III: 0003h - 00EFh) Note: The setting range changes if using MECHATROLINK-II or MECHATROLINK-III: MECHATROLINK-II (SI-T3) range: 20 to 3F MECHATROLINK-III (SI-ET3) range: 03 to EF Be sure to set a node address that is different than all other node addresses. Incorrect parameter settings will cause AEr [Station Address Setting Error] errors and the L.ERR LED on the option will come on. The drive detects AEr errors when the station address is 20 or 3F.