No.

(Hex.)

Name

Description

Default

(Range)

F6-32

(03CD)

PROFIBUS-DP Data Format Select

Sets the data format of PROFIBUS-DP communication. Restart the drive after you change the parameter setting.

0

(0 - 5)

Note:

The H5-11 [Comm ENTER Command Mode] setting makes the RAM enter command necessary or not necessary to write parameters over network communication. When F6-32 = 0, 1, or 2, the H5-11 setting does not have an effect. The RAM enter command is always necessary to write parameters.

0
PPO Type
 
1
Conventional
 
2
PPO (bit0)

This function operates when bit 0 and bit 4 in the register STW have values of 1 (operate). Refer to the PROFIBUS-DP communication manual for more information.

3
PPO (Enter)
 
4
Conventional (Enter)
 
5
PPO (bit0, Enter)

This function operates when bit 0 and bit 4 in the register STW have values of 1 (operate). Refer to the PROFIBUS-DP communication manual for more information.