No.

(Hex.)

Name

Description

Default

(Range)

C3-21

(033E)

RUN

Motor 2 Slip Compensation Gain

Sets the gain for the motor 2 slip compensation function. Usually it is not necessary to change this setting.

Determined by E3-01

(0.0 - 2.5)

Note:

Correctly set these parameters before you change the slip compensation gain:

  • E4-01 [Motor 2 Rated Current]

  • E4-02 [Motor 2 Rated Slip]

  • E4-03 [Motor 2 Rated No-Load Current]

Adjust this parameter as follows if necessary:

  • If the motor speed is slower than the frequency reference, increase C3-01 in 0.1-unit increments.

  • If the motor speed is faster than the frequency reference, decrease C3-01 in 0.1-unit increments.