No.

(Hex.)

Name

Description

Default

(Range)

C5-05

(021F)

ASR Limit

Set the ASR output limit as a percentage of E1-04 [Maximum Output Frequency].

5.0%

(0.0 - 20.0%)

If the motor rated slip is high, it is necessary to increase the setting for correct motor speed control. Use U6-04 [ASR Output] to make sure that ASR is operating at the limit set in this parameter. When ASR is operating at the limit, correctly set the PG signal and these parameters before you make changes to C5-05.

  • F1-01 [Encoder 1 Pulse Count (PPR)]

  • F1-12 [Encoder 1 Gear Teeth 1]

  • F1-13 [Encoder 1 Gear Teeth 2]