No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
C5-37
(0278)
Expert
|
Motor 2 Inertia
|
       
Sets the motor inertia for motor 2.
|
Determined by o2-04, C6-01
(0.0001 - 600.00 kgm2)
|
Note:
The display units for the default setting and setting range are different for different models:
-
0.0001 kgm2 units (setting range: 0.0001 kgm2 to 6.0000 kgm2): 2004 to 2021, 4002 to 4012
-
0.001 kgm2 units (setting range: 0.001 kgm2 to 60.000 kgm2): 2030 to 2211, 4018 to 4103
-
0.01 kgm2 units (setting range: 0.01 kgm2 to 600.00 kgm2): 2257 to 2415, 4140 to 4H12
The drive automatically sets C5-37 to the value of “Motor Inertia” when you do Inertia Tuning or ASR Tuning.