d1-17: Jog Reference

No.

(Hex.)

Name

Description

Default

(Range)

d1-17

(0292)

RUN

Jog Reference

Sets the Jog frequency reference in the units from o1-03 [Frequency Display Unit Selection]. Set H1-xx = 6 [MFDI Function Select = Jog Reference Selection] to use the Jog frequency reference.

6.00 Hz

(0.00 - 590.00 Hz)

Note:
  • The upper limit value changes when the E1-04 [Maximum Output Frequency] and d2-01 [Frequency Reference Upper Limit] values change.

  • When A1-02 = 6, 7 [Control Method Selection = AOLV/PM, CLV/PM], the drive sets o1-03 = 1 [0.01% (100% = E1-04)].