No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
E5-04
(032C)
|
PM Motor Pole Count
|
       
Sets the number of PM motor poles.
|
Determined by E5-01
(2 - 120)
|
Note:
-
When A1-02 = 7 [Control Method Selection = CLV/PM], the maximum value is 120.
-
When A1-02 = 5, 6 or 8 [OLV/PM, AOLV/PM or EZOLV], the maximum value is 48.
These types of Auto-Tuning will automatically set this parameter to the value of [Number of Motor Poles]:
-
Manual Entry w/ Motor Data Sheet
-
PM Stationary Auto-Tuning
-
Rotational (Ld, Lq, R, back-EMF)