No.
(Hex.)
|
Name
|
Description
|
Default
(Range)
|
|
E9-09
(11EC)
|
Motor Rated Slip
|
       
Sets the motor rated slip.
|
0.000 Hz
(0.000 - 20.000 Hz)
|
The setting value of this parameter is the slip compensation reference value.
The drive uses the setting values of E9-03, E9-04, and E9-08 to calculate this parameter. When Motor Rated Slip = 0, Auto-Tuning automatically sets this parameter to the value of [Motor Rated Slip].
Note: