Jump to main content

L1-19: NTC Thermistor Disconnect Select

No.

(Hex.)

Name

Description

Default

(Range)

L1-19

(0444)

Expert

NTC Thermistor Disconnect Select

Determines drive operation when the drive detects THo [Thermistor Disconnect].

1

(0 - 3)

0
Ramp to Stop

The drive ramps to stop in the set deceleration time. Fault relay output terminal MA-MC turns ON, and MB-MC turns OFF.

1
Coast to Stop

The output turns OFF and the motor coasts to stop. Fault relay output terminal MA-MC turns ON, and MB-MC turns OFF.

2
Fast Stop (Use C1-09)

The drive stops the motor in the deceleration time set in C1-09 [Fast Stop Time]. Fault relay output terminal MA-MC turns ON, and MB-MC turns OFF.

3
Alarm Only

The keypad shows Tho [Thermistor Disconnect], and the drive continues to operate. The output terminal set to H2-01 to H2-04 = 10 [Alarm] activates.