L1-20
(0445)
Expert
Motor Overheat (oH5) Selection
Sets the drive operation when the NTC input signal to the drive is at the oH5 [Motor Overheat (NTC Input)] detection level.
1
(0 - 3)
The drive ramps to stop in the set deceleration time. Fault relay output terminal MA-MC turns ON, and MB-MC turns OFF.
The output turns OFF and the motor coasts to stop. Fault relay output terminal MA-MC turns ON, and MB-MC turns OFF.
The drive stops the motor in the deceleration time set in C1-09 [Fast Stop Time]. Fault relay output terminal MA-MC turns ON, and MB-MC turns OFF.
The keypad shows oH5 [Motor Overheat (NTC Input)], and the drive continues to operate. The output terminal set to H2-01 to H2-04 = 10 [Alarm] activates.